Background
Oversedation masks neurologic changes and increases mortality/morbidity, whereas undersedation
risks prolonged stress mobilization and patient injury. In situations such as deep
sedation/analgesia, the Bispectral Index (BIS) has potential use as an adjunct to
clinical assessment of sedation to help determine depth of sedation. Determining the
correlation between clinical and BIS measures of sedation will help to determine the
correct role of BIS in intensive care unit (ICU) practice settings.
Objective
To evaluate the correlation between the clinical assessment of sedation using the
Sedation-Agitation Scale (SAS) and the assessment using BIS in ventilated and sedated
ICU patients.
Methods
ICU patients requiring mechanical ventilation and sedation were monitored using the
SAS and BIS. Nurses initiated event markers with BIS at the time of SAS assessment
but were blinded to BIS scores.
Results
Data were collected on 40 subjects generating 209 paired readings. Moderate positive
correlation between BIS and SAS values was shown with a Spearman Rank coefficient
r value of .502 and an r2 of .252 (P < .0001). Wide ranges of BIS scores were observed, especially in very sedated patients.
Strong positive correlation was noted between BIS and electromyography with an r value of .749 (P < .0001). Age and gender significantly influenced BIS/SAS correlations.
Conclusion
In situations in which the clinical assessment is equivocal, BIS monitoring may have
an adjunctive role in sedation assessment. BIS values should be interpreted with caution,
however, because electromyography activity and other factors seem to confound BIS
scores. More research is necessary to determine the role of BIS monitoring in ICU
practice.
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Heart & Lung: The Journal of Cardiopulmonary and Acute CareAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- Using and understanding sedation scoring systems: a systematic review.Intensive Care Med. 2000; 26: 275-285
- Technology overview: bispectral index.Aspect Medical Systems, Inc, Newton, MA1997
- The BIS monitor: a review and technology assessment.AANA J. 2001; 69: 477-483
- Recovery of consciousness after thiopental or propofol: bispectral index and the isolated forearm technique.Anesthesiology. 1997; 86: 613-619
- Hypnotic titration using bispectral index (BIS): anesthetic emergence and recovery.Anesthesiology. 1997; 87: A422
- Improved propofol titration using the bispectral index (BIS).Anesthesiology. 1996; 85: A351
- Bispectral analysis (BIS) monitoring improves PACU recovery from propofol alfentanil/N2O anesthesia.Anesthesiology. 1996; 85: A468
- Bispectral index (BIS) monitoring allows faster emergence from propofol alfentanil/N2O anesthesia.Anesthesiology. 1996; 85: A1056
- When is a bispectral index of 60 too low?.Anesthesiology. 2007; 106: 472-483
- Bispectral index does not correlate with observer assessment of alertness and sedation scores during .5% bupivacaine epidural anesthesia with nitrous oxide sedation.Anesth Analg. 2006; 103: 385-389
- Bispectral-index-guided versus clinically guided remifentanil/propofol analgesia/sedation for interventional radiological procedures: an observer-blinded randomized study.Anesth Analg. 2006; 103: 378-384
- Blinded BIS monitoring during ERCP shows additional sedatives are often given when patients are already in deep sedation.Gastrointest Endosc. 2005; 61: AB119
- Efficacy of Bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy: a randomized controlled trial.Am J Gastroenterol. 2006; 101: 2003-2007
- Comparison of a new bispectral index (BIS) algorithm to modified observer's assessment of alertness/sedation (MOAA/S) scale in moderate sedation.Gastrointest Endosc. 2004; 59: P128
- Review of bispectral index monitoring in the emergency department and pediatric intensive care unit.Pediatr Emerg Care. 2006; 22: 815-821
- Can the Bispectral Index monitor the sedation adequacy of intubated ED adults.Am J Emerg Med. 2004; 22: 76-82
- Value of bispectral index monitor in differentiating between moderate and deep Ramsay sedation scores in children.Paediatr Anaesth. 2006; 16: 1226-1231
- Comparison of the bispectral index monitor with the comfort score in assessing level of sedation in critically ill children.Intensive Care Med. 2003; 29: 2239-2246
- Bispectral index (BIS) monitoring of ICU patients on continuous infusion of sedatives and paralytics reduces sedative drug utilization and cost.Crit Care. 2000; 4: S110
- Bispectral index in ICU: correlation with Ramsay score on assessment of sedation level.J Clin Monit Comput. 2002; 17: 271-277
- Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation/ Agitation Scale.Crit Care Med. 1999; 27: 1499-1504
- Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients.Intensive Care Med. 1998; 24: 1294-1298
- Validating the Sedation-Agitation Scale with the Bispectral Index and Visual Analogue Scale in adult ICU patients after cardiac surgery.Intensive Care Med. 2001; 27: 853-858
- Role of bedside electroencephalography in the adult intensive care unit during therapeutic neuromuscular blockade.Crit Care. 1997; 1: 1-9
- Evaluation of the bispectral index (BIS), lorazepam concentrations (LC) and the sedation agitation scale (SAS) in critically ill surgical patients.Crit Care Med. 2005; 33: A6
- The impact of bispectral index monitoring on sedation administration in mechanically ventilated patients.Anaesth Intensive Care. 2007; 35: 204-208
- How reliable is the bispectral index in critically ill patients?.Crit Care Med. 2002; 30: 1483-1487
- Comparison of electrophysiologic monitors with clinical assessment of level of sedation.Mayo Clin Proc. 2006; 81: 46-52
- Is the bispectral index appropriate for monitoring the sedation level of mechanically ventilated surgical ICU patients?.Intensive Care Med. 2002; 28: 178-183
- Overestimation of bispectral index in sedated intensive care unit patients revealed by administration of muscle relaxant.Anesthesiology. 2003; 99: 9-17
- Comparison of two bispectral index algorithms in monitoring sedation in postoperative intensive care patients.Crit Care Med. 2005; 33: 685-687
- Using bispectral index monitoring to detect potential breakthrough awareness and limit duration of neuromuscular blockade.Am J Crit Care. 2004; 13: 66-73
- Refractory increased intracranial pressure in severe traumatic brain injury: barbiturate coma and bispectral index monitoring.AACN Clin Issues. 2005; 16: 526-541
- Bispectral index monitoring correlates with sedation scales in brain-injured patients.Crit Care Med. 2004; 32: 2403-2406
- Bispectral index compared to Ramsay score for sedation monitoring in intensive care units.Minerva Anestesiol. 2006; 72: 329-336
- Impact of bispectral index monitoring on sedation and outcomes in critically ill adults: a case series.Crit Care Nurs Clin N Am. 2006; 18: 227-241
- Role of the bispectral index in sedation monitoring in the ICU.Ann Pharmacother. 2006; 40: 490-500
- Sedation assessment in critically ill patients with bispectral index.Eur J Anaesth. 2002; 19: 18-22
- Electromyographic activity falsely elevates the bispectral index.Anesthesiology. 2000; 92: 1485-1487
- Administration of sedatives and level of sedation: comparative evaluation via the Sedation-Agitation Scale and the Bispectral Index.Am J Crit Care. 2003; 12: 343-348
- Sedation in the intensive care unit: refining the models and defining the questions.Crit Care Med. 2002; 30: 1661-1663
- The bispectral index: expanded performance for everyday use in the intensive care unit?.Crit Care Med. 2005; 33: 685-687
- Bispectral analysis technology and equipment.Minerva Anestesiol. 2000; 66: 386-388
- Bispectral index: comparison of two montages.Br J Anaesth. 1998; 80: 342-344
Article info
Publication history
Published online: January 22, 2009
Footnotes
This research was funded by the American Association of Critical Care Nurses/Sigma Theta Tau Critical Care Research Grant.
This research was performed at Christiana Care Health System in Newark, Delaware.
Identification
Copyright
© 2009 Mosby, Inc. Published by Elsevier Inc. All rights reserved.