Heart & Lung: The Journal of Acute and Critical Care
Volume 34, Issue 5 , Pages 345-359, September 2005

Variables influencing intravenous catheter insertion difficulty and failure: An analysis of 339 intravenous catheter insertions

  • Ann F. Jacobson, PhD, RN

      Affiliations

    • Kent State University College of Nursing, Kent, Ohio
    • Corresponding Author InformationReprint requests: Ann F. Jacobson, PhD, RN, Kent State University College of Nursing, PO Box 5190, Kent OH 44242.
  • ,
  • Elizabeth H. Winslow, PhD, RN (FAAN)

      Affiliations

    • Presbyterian Hospital of Dallas, Dallas, Texas

Background

Inserting an intravenous catheter (IV) is one of the most frequently performed invasive procedures by nurses. Little research has been conducted on ways to reduce the difficulty and failure, and enhance the ease and success, of IV insertion. We conducted this study to determine variables associated with IV insertion difficulty, failure, and success, and to learn special techniques nurses use to facilitate IV insertion.

Methods

Data were collected on 339 IV insertions in hospitalized patients by 34 registered nurses. The data included information about the nurse (eg, age, education, and self-rated IV insertion skill); the patient (eg, age and race); the IV (eg, site, gauge, and type); and the IV insertion, (eg, duration and difficulty). Data were analyzed to determine the effects of these variables on IV insertion outcome. In addition, nurses were asked to describe special techniques they used to facilitate IV insertion.

Results

A total of 77% of the IV insertions were successful. Nurses who were older, had more years of experience, were certified in a specialty, and rated themselves higher in insertion skill had significantly more successful insertions than their younger and less-experienced and less-skilled counterparts (P < .001). Successful IV insertions were significantly faster (mean 32 seconds) than unsuccessful ones (mean 66 seconds) (P < .001), and were rated as significantly less difficult (P < .001). Failed IV insertions were associated with higher degrees of difficulty arising from vein variables, such as vein rolled or vein was resistant to puncture, and patient variables, such as tough or dark skin and patient movement. The nurses described a wide variety of techniques to facilitate insertion success. The most frequently mentioned were getting self and patient in a comfortable position, using mechanical stimulation such as tapping the vein, and stabilizing the vein.

Conclusion

Approximately one fourth of the 339 IV insertions in this study were unsuccessful. Repeated insertion attempts are painful and costly. This study identified nurse, patient, and IV variables associated with IV insertion success and failure. Future research is needed to confirm and expand these findings and to develop interventions to improve IV insertion skills and outcomes.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 12.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Sigma Theta Tau International, Delta Xi Chapter funded this project.

PII: S0147-9563(05)00085-3

doi:10.1016/j.hrtlng.2005.04.002

Heart & Lung: The Journal of Acute and Critical Care
Volume 34, Issue 5 , Pages 345-359, September 2005